Unknown: Array and string offset access syntax with curly braces is deprecated in /home/suppli22/public_html/system/library/so_social/src/service/Google_Utils.php on line 58 Topcon CT-80 Computerized Auto Tonometer Unknown: array_key_exists(): Using array_key_exists() on objects is deprecated. Use isset() or property_exists() instead in /home/suppli22/public_html/system/library/template/Twig/Template.php on line 533
Topcon CT-80 Computerized Auto Tonometer

Topcon CT-80 Computerized Auto Tonometer

$2,200.00
Product Code: SME10136
Availability: In Stock
Viewed 2420 times

Product Description

The CT-80 Computerized Tonometer makes intraocular pressure measurements easier and more comfortable than ever before. It features a 30% faster measurement time, a triple patient safety function, and a dual sensor measuring system.

Key Features

* Innovative dual sensor system for accurate measurements
* Triple patient safety function
* New alignment bar & improved air cylinder reduces the interval time between measurements by 30%
* Built-in printer
* Fast, easy and accurate intraocular pressure readings
* Internal fixation target
* Auto alignment
* Auto measurement

SPECIFICATIONS
OPTIONL ACCESSORIES
Measurement Range
Working Distance
Measurement Display
Measurement Recording
Measurement Mode
Alignment
Error Indication
Adjustable Safety Stopper
Operating Temperature
Base Travel
Chinrest Vertical Travel
External Output Terminal
Power Supply
Power Consumption
Dimensions
Weight
0-60mmHg [0-30mmHg/0-60mmHg(Selectable)]
11mm
TV Monitor Screen
*R/L change-over・・・automatically detected and displayed.
*Up to three measurements of each eye can be displayed and printed out.
Built-in printer
Auto / Manual (selectable)
When the alignment luminous spots are within the inner alignment mark,
*In Auto Mode : measurement is automatically activated
*In Manual Mode : alignment will change from a broken box to a solid
pattern when proper alignment is achieved, and depressing the switch on
the omni-directional joystick activates the measuring cycle.
When the measurement signal is not strong enough,
IOP value is indicated in ( ) or just 'ERR' is displayed.
Minimum distance between the front of the instrument and the
patient can be established in advance.
10℃ to 40℃
44mm (back & forth) / 88mm(left & right) / 28mm(vertically)
68mm
RS-232C
AC100-120V, 220-240V 50/60Hz
80VA ("Auto-shut-off" : power saving mechanism adopted)
272(W)×505(D)×430~458(H)mm
Approx.18 kg
Adjustable Instrument Table AIT-15

Size Chart

AHP300 Transport Ventilator

$2,678.00

AutoVent 2000/3000 Automatic Transport Ventilator

$1,938.00

paraPAC plus Transport Ventilator Electric with PE..

$3,604.00

Pneupac paraPAC Plus 310

$3,943.00

Pneupac paraPAC Ventilator

$3,761.00

Pneupac ventiPAC Medical Ventilator w/ Alarms

$4,481.00

AHP300 Transport Ventilator

$2,678.00

AutoVent 2000/3000 Automatic Transport Ventilator

$1,938.00

paraPAC plus Transport Ventilator Electric with PE..

$3,604.00

Pneupac paraPAC Plus 310

$3,943.00

Pneupac paraPAC Ventilator

$3,761.00

Pneupac ventiPAC Medical Ventilator w/ Alarms

$4,481.00